The evaluation of sacroiliitis using Tc-99m-nanocolloid and Tc-99m-MDP scintigraphy


YILDIZ A., GUNGOR F., Tuncer T., KARAYALCIN B.

NUCLEAR MEDICINE COMMUNICATIONS, cilt.22, sa.7, ss.785-794, 2001 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 22 Sayı: 7
  • Basım Tarihi: 2001
  • Doi Numarası: 10.1097/00006231-200107000-00010
  • Dergi Adı: NUCLEAR MEDICINE COMMUNICATIONS
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.785-794
  • Anahtar Kelimeler: sacroiliitis, Tc-99m-nanocolloid scintigraphy, bone scanning, single photon emission computed tomography, EMISSION COMPUTED-TOMOGRAPHY, POLYCLONAL IMMUNOGLOBULIN-G, RHEUMATOID-ARTHRITIS, ACTIVE SACROILIITIS, JOINT SCINTIGRAPHY, NANOCOLLOID SCINTIGRAPHY, DISEASE-ACTIVITY, BONE-SCAN, BACK-PAIN, INFLAMMATION
  • Akdeniz Üniversitesi Adresli: Evet

Özet

The role of imaging studies in the evaluation of patients with sacroiliitis is controversial. We aimed to evaluate the role of nanocolloid and bone scintigraphy in patients with sacroiliitis and to investigate the clinical relevance of imaging findings. Thirty-two patients with clinically sacroiliac disease (nine females, 23 males, aged 22-47 years) underwent scintigraphic and radiographic examinations and all imaging studies were performed within 2 weeks. Twenty-five subjects were also included as a control group (10 females, 15 males, aged 20-51 years) for quantitative analysis of the hone scan. The quantitative analysis was done by using regions of interest drawn over the right and left sacroiliac (ST) joint and sacrum (S) and SI/S ratios were calculated. Abnormal uptake was defined as an uptake higher than the mean +/- 2 SD of the control SI/S values. Bone scintigraphy was performed using a three-phase technique and single photon emission computed tomography (SPECT). Nanocolloid scintigraphy (NS) was performed 1 h later, after administration of 370 MBq Tc-99m-nanocolloid, and evaluated visually. Each of the scintigraphic examinations was performed on separate days within the same week. Sensitivity values were 25%, 47%, 69% and 97%, and specificity values were 80%, 90%, 95% and 90% in quantitative bone scanning (QBS), Tc-99m-NS, planar and SPECT bone imaging, respectively, when the clinical findings were considered as the 'gold standard'. Our results showed that bone SPECT scanning was more sensitive than planar imaging, but planar imaging was the most specific method. SPECT was also the most associated technique with clinical findings. Tc-99m-NS was neither specific nor sensitive enough in the detection of sacroiliitis although it could be helpful fur the confirmation of inflammation. ((C) 2001 Lippincott Williams & Wilkins).